Summer is deck, pergola and shade sail season, and many of these jobs don’t need a building consent. Schedule 1 of the Building Act 2004 lists the work that’s exempt, but each item comes with limits, and getting one wrong turns a weekend project into unconsented building work.

The Act is clear that an exemption only removes the consent. Exempt work must still comply “with the building code to the extent required by this Act” and must not breach any other law, including your district plan.

Decks, pergolas and shade sails

A deck, platform, boardwalk or the like is exempt if nobody could fall more than 1.5 metres from it, “even if it collapses”.

A low deck can still need a barrier. Building Code clause F4 requires a barrier wherever people could fall 1 metre or more, so a deck between 1 and 1.5 metres off the ground can be consent-free but still need a balustrade that meets the Code.

The schedule also exempts building work in connection with a pergola. Shade sails are exempt up to 50 square metres, as long as they’re at least 1 metre from any legal boundary.

Fences, walls and outdoor fireplaces

A fence or hoarding is exempt up to 2.5 metres high. The exemption doesn’t cover a fence that restricts access to a residential pool, which has its own rules.

A retaining wall is exempt if it holds back no more than 1.5 metres of ground and doesn’t support any surcharge, meaning extra load from above.

Outdoor fireplaces and pizza ovens are exempt if they’re no more than 2.5 metres high overall, have a cooking surface of no more than 1 square metre, and sit at least 1 metre from any legal boundary or building.

Sheds, sleepouts and solar

Since 23 October 2025, a single-storey detached building of no more than 10 square metres no longer has to be set back from boundaries to stay exempt. Other building types covered by that exemption must still sit at least 1 metre from any residential building or legal boundary.

A detached sleepout or shed of 10 to 30 square metres is also exempt if it’s a single storey, built from lightweight products to the Acceptable Solution for timber or steel buildings, and has no sanitary facilities or drinking water storage. It can only include sleeping space if it’s used with a house, has no cooking facilities and has smoke alarms.

A carport of up to 20 square metres on the ground is exempt, as is a porch or veranda of up to 20 square metres attached to an existing house at ground or first-floor level.

The same 2025 changes exempted roof-mounted solar panels, as long as the arrays don’t exceed 40 square metres in total and the property is in a wind zone no higher than high.

If you’re unsure whether a project fits, check with your council before you build rather than after.

District plan rules, such as height-to-boundary and site coverage limits, can still apply to consent-exempt structures. The council’s planning team can tell you which rules apply to your section.

Licensed tradespeople still have to do the restricted parts of any job, such as electrical work for outdoor lighting or plumbing for an outdoor sink. Ask them for a certificate of compliance or a record of work, and keep it with your property records.